Agilent 1100/MSD 1956
Objektnummer | B00018588 |
---|---|
ID-number | 018588 |
Object name | Agilent 1100/MSD 1956 |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Kommentar: Dokumente dt./engl.
Vorstellung des Vakuumentgasers
Der Vakuumentgaser besteht aus einem 4-Kanal Vakuumbehälter mit 4 röhrenförmigen Kunststoffmembranen und einer Vakuumpumpe. Wird der Vakuumentgaser eingeschaltet, so schaltet die eingebaute Steuerung die Vakuumpumpe ein und diese erzeugt ein Vakuum im Vakuumbehälter. Das Vakuum wird mit einem Vakuumsensor überwacht. Der Vakuumentgaser hält das Vakuum durch ein- und ausschalten der Pumpe, in Abhängigkeit vom Sensorsignal, aufrecht.
Die LC-Pumpe saugt dabei die Lösungsmittel aus den Vorratsflaschen durch die speziellen Kunststoffmembranen im Vakuumbehälter. Bei der Passage der Lösungsmittel durch die Vakuumleitung diffundieren die im Lösungsmittel gelösten Gase durch die Membran in den Vakuumbehälter. Die Lösungsmittel werden dabei nahezu vollständig entgast, wenn sie den Ausgang des Vakuumentgasers erreichen.
Physikalische Spezifikationen
Typ |
Spezifikation |
Kommentar |
Gewicht |
7 kg |
|
Abmessungen (Breite x Tiefe x Höhe) |
345 x 435 x 80 mm (13.5 x 17 x 3.1 Zoll) |
|
Netzstrom |
100-120 oder 220 - 240 V, ± 10 % |
über einen weiten Bereich |
Netzfrequenz |
50 oder 60 Hz, ± 5 % |
|
Leistungsaufnahme |
30W |
Maximum |
Zulässige Umgebungstemperatur |
0 - 55 °C (32 - 131 °F) |
|
Unzulässige Umgebungstemperatur |
-40 - 70 °C (-4 - 158 °F) |
|
Feuchtigkeit |
<95 %, bei 25-40 °C (77 -104 °F) |
nicht kondensierend |
Zulässige Höhe |
Bis zu 2000 m (6500 ft) |
|
Unzulässige Höhe |
Bis zu 4600 m (14950 ft) |
zur Aufbewahrung |
Sicherheitsstandards: IEC, CSA, UL |
Installation Kategorie II, Verunreinigungsgrad 2 |
|
Binary gradient pump:
Hydraulic System: |
Two dual-pistons in series, with proprietary servocontrolled variable stroke drive, floating pistons and active inlet valve |
Flow range: |
Setpoints from 0.001 to 5.0 ml/min, in 0.001 ml/min increments |
Pressure: |
Operating range 0-40 Mpa (0-400 bar, 0-5880 psi) |
Gradient formation: |
High pressure binary mixing Delay volume 180-480 pl (600-900 ul with mixer), dependent on back pressure |
Composition precision: |
< 0.20 % SD, at 0.1 and 1.0 ml/min |
Dimensions (h x w x d): |
180 x 345 x 435 mm (7 x 13.5 x 17 inches) |
Weight: |
15.5 kg (341bs) |
Agilent 1100 Series well-plate autosampler
Sample capacity: |
2 well plates (96 and 384) plus 10 additional 2 ml vials or up to 100 vials |
Injection volume: |
0.1-100 pl standard injection range. Up to 1500 PI with multipledraw (hardware modification required) |
Precision: |
Typically < 0.5% from 5-100 pl, < 1 % from 1-5 pl |
Carry over: |
< 0.01 % using the following conditions: Column : 125 x 4 mm Hypersil ODS, 5 pm Mobile phase : water/ acetonitrile=80/20 Flow rate : 1ml/min Inj.vol. : 1 pl caffeine (1mg/ml), 5 µl water to test carry over Outside wash of needle before injection : 20 sec. with water using flush port |
Agilent 1100 Series LC/MSD System
The Agilent 1100 Series LC/MSD is a benchtop Mass Selective Detector for the Agilent 1100 Series LC that gives laboratories the powerful mass spectral information and the exceptional ease of use needed to improve laboratory throughput.
With the latest in usability, productivity, and performance, the Agilent LC/MSD helps laboratories support faster product development cycles and improve the quality of analytical results. The Agilent LC/MSD is designed specifically for the liquid chromatographer. It features easy-to-use detector hardware, stable and reliable operation, software to turn mass spectral data into useful information, and complete integration with the Agilent 1100 Series modules and systems for HPLC.
The Agilent LC/MSD software is fully integrated with the Microsoft Windows-based Agilent 3D LC ChemStation software. Users familiar with Agilent's 3D LC ChemStation can use the system immediately. Both UV and mass spectral data are processed together using the same software tools. The Agilent ChemStation is compatible with the latest in networking technologies.
For greatest ease-of-use and highest productivity:
Instruments can be controlled and their operating status checked from any PC - even if it is not in the laboratory.
Complete web-page-ready reports can be sent directly to your desktop.
Specifications
Mass range
VL - m/z 50 - 1500
SL - m/z 50-3000
Mass accuracy
± 0.13 u within the calibrated mass range in scan mode
Mass axis stability
± 0.13 u over 8 hours
SIM sensitivity
API-electrospray at 400 µl/min or
APCI at 1000 µl/min
Selected ion monitoring of m/z 609.3
Positive ionization
Quantity Signal-to-Noise Ratio
VL 10 pg 50:1 RMS
reserpine (10:1 peak-to-peak)
SL 1 pg 50:1 RMS
reserpine (10:1 peak-to-peak)
Scan sensitivity
API-electrospray at 400 µl/min or
APCI at 1000 µl/min
Scan range m/z 100 - 650
Extracted ion at m/z 609.3
Positive ionization
Quantity Signal-to-Noise Ratio
SL 50 pg 50:1 RMS
reserpine (10:1 peak-to-peak)
Multiple signal acquisition
(SL model only)
Ability to cycle through four different acquisition modes on a scan-by-scan basis within a single run.
ISO 9001
The Agilent 1100 Series LC/MSD has been designed and manufactured under a quality system that has been registered to ISO 9001.
N 2 -Generator
SPECIFICATIONS FOR SINGLE UNIT MODEL:
Nitrogen purity: |
95.0% - 99.5% |
Atmospheric dewpoint: |
-58°F; 50°C |
Suspended liquid:s |
None |
Min./Max. operating pressure: |
60/145 psig (4/10 bar) |
Inlet temperature: |
77°F; 25°C |
Dimensions: |
50" h x 16" w x 16 d; |
|
127 cm x40 cm x40 cm |
Shipping weight: |
75 Ibs; 34 kg |
Electrical requirements |
|
HP Part Nu. 5183-2003: |
None |
HP Part Nu. 5183-2004: |
100-220 volt, 50/60Hz |