3nh TS8510 Farbmessgerät
Optical Geometry: Reflectance D/8, SCI, SCE, Include/Exclude UV, Transmittance D/0, HAZE.
Standards met: CIE No. 15, GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164,DIN5033 Part7,JIS Z8722 under condition C.
Characteristics:
Used in paints, inks, textiles, clothing, dyeing and
Printing industry etc. for color transfer and quality control.
Integrated scissor size: 154 mm.
Light source: combined LED light, UV light.
Wavelength range: 360-780nm. Wavelength interval: 10nm.
Color space: CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,
HunterLab,ßxy,DIN Lab99.
Observer angle: 2°/10.
Light source: 65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,
CWF,DLF,TL83,TL84, TPL5,U30,B,U35,NBF.
Size: LxWxH: 440 x 248 x 283 mm.
Display: 10.5-inch rotatable display pad.
Data connection: USB, Bluetooth 5.0.
Data storage: 64G storage over 100000 pieces.
NEW! Manufacturer's guarantee!
| Objektnummer | B00042588 |
|---|---|
| ID-number | 42588 |
| Object name | 3nh TS8510 Farbmessgerät |
| Manufacture | 3nh |
| Shipping | 3-4 weeks |
| Status | Provider |
Product group: Colour measurement systems
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer: 3nh
model: TS8510
The following illustrations and descriptions refer to the instrument model and are drawn from brochures.
They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
Specification
| Model | TS8510 (LED Light source) |
| Optical Geometry | Reflect: D/8 (diffused illumination, 8-degree viewing angle) ; |
| SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source ; | |
| Transmittance: D/0 (diffuse illumination: 0° viewing) ; | |
| SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source ; | |
| HAZE (ASTM D1003); | |
| Standards meet: CIE No.15, GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164,DIN5033 Teil7,JIS Z8722 under condition C | |
| Characteristic | 1. Widely applied in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
| 2. 10.5 inch rotatable display pad,128G storage,camera locating | |
| 3. Instrument can be measured on the side, upward measurement, and the downward measurement (use accessories) and other gestures. | |
| 4. Open transmission warehouse, available thickness of 54mm transmitted samples. | |
| 5. Automatic temperature and humidity compensation function. | |
| Integrating Sphere Size | Φ154mm |
| Light Source Device | 360nm–780nm Wavelength range, combined LED Light. Including UV, 400nm cut-off light source, 420nm Cut-off light source, 460nm Cut-off light source |
| Spectrophotometric Mode | Concave Grating |
| Sensor | 256 Image Element Double Array CMOS Image Sensor |
| Wavelength Range | 360~780nm |
| Wavelength Interval | 10nm |
| Semiband Width | 5nm |
| Measured Reflectance Range | 0~200% |
| Reflectivity Resolution | 0.01 |
| Measuring Aperture | Reflectiveï¼ |
| XLAV Φ25.4mm/Φ30mm, LAVΦ15mm/Φ18mm , MAVΦ8mm/Φ10mm, SAVΦ4mm/Φ6mm |
|
| Transmissive: | |
| Φ25.4mm(No limit on sample height and width, but thickness≤54mm) | |
| Remark: | |
| 1. Automatic identification of aperture switch | |
| 2. Customized Configuration caliber and lens position | |
| Specular Component | Reflectance: SCI&SCE / Transmittance: SCI&SCE |
| Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
| Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99, ΔE(Hunter), ΔE*CH, 555 Index |
| Other Colorimetric Index | WI(ASTM E313,CIE/ISO,AATCC,Hunter,Taube,Berger Stensby) |
| YI(ASTM D1925,ASTM 313),ISO brightness,R457 | |
| MI (Metamerism Index), | |
| Staining Fastness, Color Fastness, Color Strength, Opacity, | |
| APHA/Hazen/Pt-Co Index,Gardner Index | |
| Haze, Transmission(ASTM D1003), Saybolt index, ASTM D1500 Color code, 8° Gloss, 555 Index, carbon(My,dM),Color density CMYK(A,T,E,M), Tint, Color density(part function achieved via software in PC) | |
| Observer Angle | 2°/10° |
| Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30,B,U35,NBF |
| ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-C2,LED-C3,LED-C5, customized light source(41 light sources in total,part achieved via software in PC) | |
| Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset, Color assessment, haze, liquid chromaticity |
| Measuring Time | 2.0sï¼Measure SCI & SCE meantime about 4s ) |
| Repeatability | Reflectance chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration); |
| spectrum reflectance /transmissionï¼≤0.1% | |
| Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.15 (Average for 12 BCRA Series II color tiles) |
| Dimension | L*W*H=440x248x283mm |
| Weight | Approx. 13.5kg |
| Power | AC 24V, 3A Power adapter power supply |
| Illuminant Life Span | 5 years, more than 3 million times measurements |
| Display | 10.5-inch rotatable Display Pad |
| Data Port | USB & Bluetooth 5.0 |
| Data Storage | 64G storage, above 100000pcs |
| Language | Simplified Chinese, Traditional Chinese, English,(Optional Customized German,Russian, French ,Spanish ,Japanese, Thai, Korean, Polish, Portuguese) |
| Operating Environment | 0~40âï¼32~104°Fï¼ |
| Storage Environment | -20~50âï¼-4~122°Fï¼ |
| Standard Accessory | Power Adapter, User Guide, U Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber,Transmissive Test Component, cuvette, 10.5-inch screen |
| Optional Accessory | Micro Aperture(4mm) transmission test clamp component, Instrument inversion components,culture dish,Film fixture |
| Notes | Test reports can be printed through a network printer connected to a PC or display pad, The specifications are subject to change without notice. |